CVE-2026-131196
7.5, altoSplunk Enterprise NULL Pointer Dereference Vulnerability
- CVSS
- 7.5, alto alta CVSS v3.1
- EPSS, prossimi 30 giorni
- n.d.
- Sfruttamento
- Nessuna prova pubblica
- Pubblicata
- 19 nov 2026ieri
Descrizione
In Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.17, an unauthenticated user who can connect to a Splunk-to-Splunk (S2S) data forwarding receiver could cause the Splunk daemon to terminate unexpectedly. The unexpected termination interrupts data indexing and access to the management API and Splunk Web until the Splunk Enterprise process restarts. The vulnerability is possible because the S2S data forwarding receiver does not validate an optional field in forwarded event data, which results in a null pointer dereference when the field is missing. For more information see Intermediate data routing using universal and heavy forwarders (https://help.splunk.com/en/splunk-enterprise/get-started/splunk-validated-architectures/getting-data-in-forwarding-and-preprocessing/intermediate-data-routing-using-universal-and-heavy-forwarders) in the Splunk documentation.
Dettagli
- Vendor
- Splunk
- Prodotto
- Splunk Enterprise
- Debolezza
- CWE-476 (si apre in una nuova scheda)
- Stato
- Ricevuta
- Aggiornata
- 19 nov 2026
- Assegnata da
- psirt@cisco.com
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Riferimenti 1
Il tipo è ricavato dai tag di NVD dove ci sono, altrimenti dalla forma dell'URL: consideratelo un indizio.
Altre CVE di Splunk
Tutte le CVE di Splunk che abbiamoStesso vendor in ciò che abbiamo, non un legame noto fra le falle.
- CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability KEV EPSS 97% 9.8, critico
- CVE-2026-76535 Splunk Enterprise Improper Authentication Vulnerability 9.1, critico
- CVE-2026-76536 Splunk Enterprise Improper Authentication Vulnerability 9.4, critico
- CVE-2026-131175 In Splunk Enterprise versions below 10.4.4, 10.2.8, 10.0.11, and 9.4.16, a user who holds the "power" Splunk role could create and share… 7.6, alto
- CVE-2026-131177 Splunk Enterprise Injection Vulnerability 7.1, alto
- CVE-2026-131181 In Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.16, a user who does not hold the "admin" or "power" Splunk roles… 7.1, alto
- CVE-2026-131182 In Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.17, a user who holds the "power" Splunk role could store malicious… 7.6, alto
- CVE-2026-131190 Splunk Enterprise Use of Hard-coded Credentials Vulnerability 7.5, alto
Oltre questa pagina
CVE-2026-131196 è nella vostra rete?
Questa pagina vi dice quanto è pericolosa CVE-2026-131196 in circolazione. Se si trova su uno dei vostri dispositivi, può dirlo solo una scansione della vostra rete. È quello che i nostri sistemi fanno ogni giorno per le aziende che proteggiamo.
-
EXYS7600 OCELOT
Trovarla prima degli attaccanti
Ocelot scansiona la vostra rete a intervalli pianificati e segnala ogni vulnerabilità che trova con il suo identificativo CVE, il punteggio CVSS e quanti dei vostri host sono interessati. Un risultato come CVE-2026-131196 arriva con i dispositivi da aggiornare.
Scoprite EXYS7600 OCELOT -
EXYS7950 KONDRA
Rilevarla se viene sfruttata
Finché la patch non è installata, Kondra sorveglia rete, eventi ed endpoint in tempo reale. Tiene l'inventario del software installato su ogni endpoint, e le sue regole di rilevamento delle anomalie segnalano cosa fa un attaccante una volta entrato.
Scoprite EXYS7950 KONDRA
Dati compilati dall'API NVD 2.0, dal catalogo CISA Known Exploited Vulnerabilities e da FIRST EPSS. I punteggi si riferiscono alla nostra ultima raccolta del 20 nov 2026, non allo stato attuale delle fonti.